aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorAnton Vorontsov <avorontsov@ru.mvista.com>2009-03-22 21:30:52 -0700
committerDavid S. Miller <davem@davemloft.net>2009-03-22 21:30:52 -0700
commit61fa9dcf9329cb92c220f7b656410fbe5e72f933 (patch)
treef8b375ca64e3af7c5f12ab2e9d1a590f76a110cc
parente3162d381fc359ebe5c98a3e216888a7cb200051 (diff)
ucc_geth: Fix oops when using fixed-link support
commit b1c4a9dddf09fe99b8f88252718ac5b357363dc4 ("ucc_geth: Change uec phy id to the same format as gianfar's") introduced a regression in the ucc_geth driver that causes this oops when fixed-link is used: Unable to handle kernel paging request for data at address 0x00000000 Faulting instruction address: 0xc0151270 Oops: Kernel access of bad area, sig: 11 [#1] TMCUTU NIP: c0151270 LR: c0151270 CTR: c0017760 REGS: cf81fa60 TRAP: 0300 Not tainted (2.6.29-rc8) MSR: 00009032 <EE,ME,IR,DR> CR: 24024042 XER: 20000000 DAR: 00000000, DSISR: 20000000 TASK = cf81cba0[1] 'swapper' THREAD: cf81e000 GPR00: c0151270 cf81fb10 cf81cba0 00000000 c0272e20 c025f354 00001e80 cf86b08c GPR08: d1068200 cffffb74 06000000 d106c200 42024042 10085148 0fffd000 0ffc81a0 GPR16: 00000001 00000001 00000000 007ffeb0 00000000 0000c000 cf83f36c cf83f000 GPR24: 00000030 cf83f360 cf81fb20 00000000 d106c200 20000000 00001e80 cf83f360 NIP [c0151270] ucc_geth_open+0x330/0x1efc LR [c0151270] ucc_geth_open+0x330/0x1efc Call Trace: [cf81fb10] [c0151270] ucc_geth_open+0x330/0x1efc (unreliable) [cf81fba0] [c0187638] dev_open+0xbc/0x12c [cf81fbc0] [c0187e38] dev_change_flags+0x8c/0x1b0 This patch fixes the issue by removing offending (and somewhat duplicate) code from init_phy() routine, and changes _probe() function to use uec_mdio_bus_name(). Also, since we fully construct phy_bus_id in the _probe() routine, we no longer need ->phy_address and ->mdio_bus fields in ucc_geth_info structure. I wish the patch would be a bit shorter, but it seems like the only way to fix the issue in a sane way. Luckily, the patch has been tested with real PHYs and fixed-link, so no further regressions expected. Reported-by: Joakim Tjernlund <Joakim.Tjernlund@transmode.se> Signed-off-by: Anton Vorontsov <avorontsov@ru.mvista.com> Tested-by: Joakim Tjernlund <Joakim.Tjernlund@transmode.se> Signed-off-by: David S. Miller <davem@davemloft.net>
-rw-r--r--drivers/net/ucc_geth.c34
-rw-r--r--drivers/net/ucc_geth.h3
2 files changed, 11 insertions, 26 deletions
diff --git a/drivers/net/ucc_geth.c b/drivers/net/ucc_geth.c
index e87986867ba..1f61e42c641 100644
--- a/drivers/net/ucc_geth.c
+++ b/drivers/net/ucc_geth.c
@@ -1536,32 +1536,15 @@ static void adjust_link(struct net_device *dev)
static int init_phy(struct net_device *dev)
{
struct ucc_geth_private *priv = netdev_priv(dev);
- struct device_node *np = priv->node;
- struct device_node *phy, *mdio;
- const phandle *ph;
- char bus_name[MII_BUS_ID_SIZE];
- const unsigned int *id;
+ struct ucc_geth_info *ug_info = priv->ug_info;
struct phy_device *phydev;
- char phy_id[BUS_ID_SIZE];
priv->oldlink = 0;
priv->oldspeed = 0;
priv->oldduplex = -1;
- ph = of_get_property(np, "phy-handle", NULL);
- phy = of_find_node_by_phandle(*ph);
- mdio = of_get_parent(phy);
-
- id = of_get_property(phy, "reg", NULL);
-
- of_node_put(phy);
- of_node_put(mdio);
-
- uec_mdio_bus_name(bus_name, mdio);
- snprintf(phy_id, sizeof(phy_id), "%s:%02x",
- bus_name, *id);
-
- phydev = phy_connect(dev, phy_id, &adjust_link, 0, priv->phy_interface);
+ phydev = phy_connect(dev, ug_info->phy_bus_id, &adjust_link, 0,
+ priv->phy_interface);
if (IS_ERR(phydev)) {
printk("%s: Could not attach to PHY\n", dev->name);
@@ -3629,10 +3612,12 @@ static int ucc_geth_probe(struct of_device* ofdev, const struct of_device_id *ma
ug_info->uf_info.irq = irq_of_parse_and_map(np, 0);
fixed_link = of_get_property(np, "fixed-link", NULL);
if (fixed_link) {
- snprintf(ug_info->mdio_bus, MII_BUS_ID_SIZE, "0");
- ug_info->phy_address = fixed_link[0];
+ snprintf(ug_info->phy_bus_id, sizeof(ug_info->phy_bus_id),
+ PHY_ID_FMT, "0", fixed_link[0]);
phy = NULL;
} else {
+ char bus_name[MII_BUS_ID_SIZE];
+
ph = of_get_property(np, "phy-handle", NULL);
phy = of_find_node_by_phandle(*ph);
@@ -3643,7 +3628,6 @@ static int ucc_geth_probe(struct of_device* ofdev, const struct of_device_id *ma
prop = of_get_property(phy, "reg", NULL);
if (prop == NULL)
return -1;
- ug_info->phy_address = *prop;
/* Set the bus id */
mdio = of_get_parent(phy);
@@ -3657,7 +3641,9 @@ static int ucc_geth_probe(struct of_device* ofdev, const struct of_device_id *ma
if (err)
return -1;
- snprintf(ug_info->mdio_bus, MII_BUS_ID_SIZE, "%x", res.start);
+ uec_mdio_bus_name(bus_name, mdio);
+ snprintf(ug_info->phy_bus_id, sizeof(ug_info->phy_bus_id),
+ "%s:%02x", bus_name, *prop);
}
/* get the phy interface type, or default to MII */
diff --git a/drivers/net/ucc_geth.h b/drivers/net/ucc_geth.h
index 16cbe42ba43..611bdef2402 100644
--- a/drivers/net/ucc_geth.h
+++ b/drivers/net/ucc_geth.h
@@ -1091,8 +1091,7 @@ struct ucc_geth_info {
u32 eventRegMask;
u16 pausePeriod;
u16 extensionField;
- u8 phy_address;
- char mdio_bus[MII_BUS_ID_SIZE];
+ char phy_bus_id[BUS_ID_SIZE];
u8 weightfactor[NUM_TX_QUEUES];
u8 interruptcoalescingmaxvalue[NUM_RX_QUEUES];
u8 l2qt[UCC_GETH_VLAN_PRIORITY_MAX];