aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorVenki Pallipadi <venkatesh.pallipadi@intel.com>2007-10-12 23:04:23 +0200
committerThomas Gleixner <tglx@inhelltoy.tec.linutronix.de>2007-10-12 23:04:23 +0200
commit610bf2f143b9c5cda768a2d428d66d3a16769930 (patch)
tree9f64231575df918338f2ef87ddee0483d6396422
parent4a93232dab0a07074bcc5291a0f1f39919916f31 (diff)
x86: HPET restructure hpet code for hpet force enable
Restructure and rename legacy replacement mode HPET timer support. Just the code structural changes and should be zero functionality change. Signed-off-by: Venkatesh Pallipadi <venkatesh.pallipadi@intel.com> Cc: Andi Kleen <ak@suse.de> Cc: john stultz <johnstul@us.ibm.com> Cc: Greg KH <greg@kroah.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Ingo Molnar <mingo@elte.hu> Signed-off-by: Arjan van de Ven <arjan@linux.intel.com> Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
-rw-r--r--arch/x86/kernel/hpet.c148
1 files changed, 83 insertions, 65 deletions
diff --git a/arch/x86/kernel/hpet.c b/arch/x86/kernel/hpet.c
index 078dbc6d80e..ce3bcc4334d 100644
--- a/arch/x86/kernel/hpet.c
+++ b/arch/x86/kernel/hpet.c
@@ -149,9 +149,9 @@ static void hpet_reserve_platform_timers(unsigned long id) { }
*/
static unsigned long hpet_period;
-static void hpet_set_mode(enum clock_event_mode mode,
+static void hpet_legacy_set_mode(enum clock_event_mode mode,
struct clock_event_device *evt);
-static int hpet_next_event(unsigned long delta,
+static int hpet_legacy_next_event(unsigned long delta,
struct clock_event_device *evt);
/*
@@ -160,8 +160,8 @@ static int hpet_next_event(unsigned long delta,
static struct clock_event_device hpet_clockevent = {
.name = "hpet",
.features = CLOCK_EVT_FEAT_PERIODIC | CLOCK_EVT_FEAT_ONESHOT,
- .set_mode = hpet_set_mode,
- .set_next_event = hpet_next_event,
+ .set_mode = hpet_legacy_set_mode,
+ .set_next_event = hpet_legacy_next_event,
.shift = 32,
.irq = 0,
};
@@ -178,7 +178,7 @@ static void hpet_start_counter(void)
hpet_writel(cfg, HPET_CFG);
}
-static void hpet_enable_int(void)
+static void hpet_enable_legacy_int(void)
{
unsigned long cfg = hpet_readl(HPET_CFG);
@@ -187,7 +187,39 @@ static void hpet_enable_int(void)
hpet_legacy_int_enabled = 1;
}
-static void hpet_set_mode(enum clock_event_mode mode,
+static void hpet_legacy_clockevent_register(void)
+{
+ uint64_t hpet_freq;
+
+ /* Start HPET legacy interrupts */
+ hpet_enable_legacy_int();
+
+ /*
+ * The period is a femto seconds value. We need to calculate the
+ * scaled math multiplication factor for nanosecond to hpet tick
+ * conversion.
+ */
+ hpet_freq = 1000000000000000ULL;
+ do_div(hpet_freq, hpet_period);
+ hpet_clockevent.mult = div_sc((unsigned long) hpet_freq,
+ NSEC_PER_SEC, 32);
+ /* Calculate the min / max delta */
+ hpet_clockevent.max_delta_ns = clockevent_delta2ns(0x7FFFFFFF,
+ &hpet_clockevent);
+ hpet_clockevent.min_delta_ns = clockevent_delta2ns(0x30,
+ &hpet_clockevent);
+
+ /*
+ * Start hpet with the boot cpu mask and make it
+ * global after the IO_APIC has been initialized.
+ */
+ hpet_clockevent.cpumask = cpumask_of_cpu(smp_processor_id());
+ clockevents_register_device(&hpet_clockevent);
+ global_clock_event = &hpet_clockevent;
+ printk(KERN_DEBUG "hpet clockevent registered\n");
+}
+
+static void hpet_legacy_set_mode(enum clock_event_mode mode,
struct clock_event_device *evt)
{
unsigned long cfg, cmp, now;
@@ -228,12 +260,12 @@ static void hpet_set_mode(enum clock_event_mode mode,
break;
case CLOCK_EVT_MODE_RESUME:
- hpet_enable_int();
+ hpet_enable_legacy_int();
break;
}
}
-static int hpet_next_event(unsigned long delta,
+static int hpet_legacy_next_event(unsigned long delta,
struct clock_event_device *evt)
{
unsigned long cnt;
@@ -273,58 +305,11 @@ static struct clocksource clocksource_hpet = {
#endif
};
-/*
- * Try to setup the HPET timer
- */
-int __init hpet_enable(void)
+static int hpet_clocksource_register(void)
{
- unsigned long id;
- uint64_t hpet_freq;
u64 tmp, start, now;
cycle_t t1;
- if (!is_hpet_capable())
- return 0;
-
- hpet_set_mapping();
-
- /*
- * Read the period and check for a sane value:
- */
- hpet_period = hpet_readl(HPET_PERIOD);
- if (hpet_period < HPET_MIN_PERIOD || hpet_period > HPET_MAX_PERIOD)
- goto out_nohpet;
-
- /*
- * The period is a femto seconds value. We need to calculate the
- * scaled math multiplication factor for nanosecond to hpet tick
- * conversion.
- */
- hpet_freq = 1000000000000000ULL;
- do_div(hpet_freq, hpet_period);
- hpet_clockevent.mult = div_sc((unsigned long) hpet_freq,
- NSEC_PER_SEC, 32);
- /* Calculate the min / max delta */
- hpet_clockevent.max_delta_ns = clockevent_delta2ns(0x7FFFFFFF,
- &hpet_clockevent);
- hpet_clockevent.min_delta_ns = clockevent_delta2ns(0x30,
- &hpet_clockevent);
-
- /*
- * Read the HPET ID register to retrieve the IRQ routing
- * information and the number of channels
- */
- id = hpet_readl(HPET_ID);
-
-#ifdef CONFIG_HPET_EMULATE_RTC
- /*
- * The legacy routing mode needs at least two channels, tick timer
- * and the rtc emulation channel.
- */
- if (!(id & HPET_ID_NUMBER))
- goto out_nohpet;
-#endif
-
/* Start the counter */
hpet_start_counter();
@@ -346,7 +331,7 @@ int __init hpet_enable(void)
if (t1 == read_hpet()) {
printk(KERN_WARNING
"HPET counter not counting. HPET disabled\n");
- goto out_nohpet;
+ return -ENODEV;
}
/* Initialize and register HPET clocksource
@@ -367,15 +352,48 @@ int __init hpet_enable(void)
clocksource_register(&clocksource_hpet);
+ return 0;
+}
+
+/*
+ * Try to setup the HPET timer
+ */
+int __init hpet_enable(void)
+{
+ unsigned long id;
+
+ if (!is_hpet_capable())
+ return 0;
+
+ hpet_set_mapping();
+
+ /*
+ * Read the period and check for a sane value:
+ */
+ hpet_period = hpet_readl(HPET_PERIOD);
+ if (hpet_period < HPET_MIN_PERIOD || hpet_period > HPET_MAX_PERIOD)
+ goto out_nohpet;
+
+ /*
+ * Read the HPET ID register to retrieve the IRQ routing
+ * information and the number of channels
+ */
+ id = hpet_readl(HPET_ID);
+
+#ifdef CONFIG_HPET_EMULATE_RTC
+ /*
+ * The legacy routing mode needs at least two channels, tick timer
+ * and the rtc emulation channel.
+ */
+ if (!(id & HPET_ID_NUMBER))
+ goto out_nohpet;
+#endif
+
+ if (hpet_clocksource_register())
+ goto out_nohpet;
+
if (id & HPET_ID_LEGSUP) {
- hpet_enable_int();
- /*
- * Start hpet with the boot cpu mask and make it
- * global after the IO_APIC has been initialized.
- */
- hpet_clockevent.cpumask = cpumask_of_cpu(smp_processor_id());
- clockevents_register_device(&hpet_clockevent);
- global_clock_event = &hpet_clockevent;
+ hpet_legacy_clockevent_register();
return 1;
}
return 0;