hwmon: (it87) Prevent power-off on Shuttle SN68PT
On the Shuttle SN68PT, FAN_CTL2 is apparently not connected to a fan, but to something else. One user has reported instant system power-off when changing the PWM2 duty cycle, so we disable it. I use the board name string as the trigger in case the same board is ever used in other systems. This closes lm-sensors ticket #2349: pwmconfig causes a hard poweroff http://www.lm-sensors.org/ticket/2349 Signed-off-by: Jean Delvare <khali@linux-fr.org>