diff options
author | Christof Schmitt <christof.schmitt@de.ibm.com> | 2008-11-04 16:35:10 +0100 |
---|---|---|
committer | James Bottomley <James.Bottomley@HansenPartnership.com> | 2008-11-05 12:47:19 -0500 |
commit | 77fd9494bce3188c20d82e45464ed9b1be83bf98 (patch) | |
tree | fde00a1b349fa77a478aadb62bf91f24e63f257e /drivers/s390 | |
parent | adc90daffbb454eeae00df92855a88ba79b5b636 (diff) |
[SCSI] zfcp: Wait for port scan to complete when setting adapter online
Attaching a unit immediately after setting the adapter online should
be possible. The problem right now is that the port_scan runs from a
workqueue and has not finished when the set_online call returns and
the sysfs structures for the ports are not available yet. Fix that by
waiting for the port scan to complete.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Diffstat (limited to 'drivers/s390')
-rw-r--r-- | drivers/s390/scsi/zfcp_ccw.c | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/drivers/s390/scsi/zfcp_ccw.c b/drivers/s390/scsi/zfcp_ccw.c index b04038c7478..951a8d409d1 100644 --- a/drivers/s390/scsi/zfcp_ccw.c +++ b/drivers/s390/scsi/zfcp_ccw.c @@ -116,7 +116,9 @@ static int zfcp_ccw_set_online(struct ccw_device *ccw_device) zfcp_erp_adapter_reopen(adapter, ZFCP_STATUS_COMMON_ERP_FAILED, 85, NULL); zfcp_erp_wait(adapter); - goto out; + up(&zfcp_data.config_sema); + flush_work(&adapter->scan_work); + return 0; out_scsi_register: zfcp_erp_thread_kill(adapter); |