[PATCH] cciss: fix for 2TB support
This patch changes the way we determine if a logical volume is larger than 2TB. The original test looked for a total_size of 0. Originally we added 1 to the total_size. That would make our read_capacity return size 0 for >2TB lv's. We assumed that we could not have a lv size of 0 so it seemed OK until we were in a clustered system. The backup node would see a size of 0 due to the reservation on the drive. That caused the driver to switch to 16-byte CDB's which are not supported on older controllers. After that everything was broken. It may seem petty but I don't see the value in trying to determine if the LBA is beyond the 2TB boundary. That's why when we switch we use 16-byte CDB's for all read/write operations. Please consider this for inclusion. Signed-off-by: Mike Miller <mike.miller@hp.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'drivers')
-rw-r--r--drivers/block/cciss.c39
1 files changed, 24 insertions, 15 deletions
diff --git a/drivers/block/cciss.c b/drivers/block/cciss.c
index 05dfe357527..8791e43cad5 100644
--- a/drivers/block/cciss.c
+++ b/drivers/block/cciss.c
@@ -1291,13 +1291,19 @@ static void cciss_update_drive_info(int ctlr, int drv_index)
if (inq_buff == NULL)
goto mem_msg;
+ /* testing to see if 16-byte CDBs are already being used */
+ if (h->cciss_read == CCISS_READ_16) {
+ cciss_read_capacity_16(h->ctlr, drv_index, 1,
+ &total_size, &block_size);
+ goto geo_inq;
+ }
+
cciss_read_capacity(ctlr, drv_index, 1,
&total_size, &block_size);
- /* total size = last LBA + 1 */
- /* FFFFFFFF + 1 = 0, cannot have a logical volume of size 0 */
- /* so we assume this volume this must be >2TB in size */
- if (total_size == (__u32) 0) {
+ /* if read_capacity returns all F's this volume is >2TB in size */
+ /* so we switch to 16-byte CDB's for all read/write ops */
+ if (total_size == 0xFFFFFFFFULL) {
cciss_read_capacity_16(ctlr, drv_index, 1,
&total_size, &block_size);
h->cciss_read = CCISS_READ_16;
@@ -1306,6 +1312,7 @@ static void cciss_update_drive_info(int ctlr, int drv_index)
h->cciss_read = CCISS_READ_10;
h->cciss_write = CCISS_WRITE_10;
}
+geo_inq:
cciss_geometry_inquiry(ctlr, drv_index, 1, total_size, block_size,
inq_buff, &h->drv[drv_index]);
@@ -1917,13 +1924,14 @@ static void cciss_geometry_inquiry(int ctlr, int logvol,
drv->raid_level = inq_buff->data_byte[8];
}
drv->block_size = block_size;
- drv->nr_blocks = total_size;
+ drv->nr_blocks = total_size + 1;
t = drv->heads * drv->sectors;
if (t > 1) {
- unsigned rem = sector_div(total_size, t);
+ sector_t real_size = total_size + 1;
+ unsigned long rem = sector_div(real_size, t);
if (rem)
- total_size++;
- drv->cylinders = total_size;
+ real_size++;
+ drv->cylinders = real_size;
}
} else { /* Get geometry failed */
printk(KERN_WARNING "cciss: reading geometry failed\n");
@@ -1953,16 +1961,16 @@ cciss_read_capacity(int ctlr, int logvol, int withirq, sector_t *total_size,
ctlr, buf, sizeof(ReadCapdata_struct),
1, logvol, 0, NULL, TYPE_CMD);
if (return_code == IO_OK) {
- *total_size = be32_to_cpu(*(__u32 *) buf->total_size)+1;
+ *total_size = be32_to_cpu(*(__u32 *) buf->total_size);
*block_size = be32_to_cpu(*(__u32 *) buf->block_size);
} else { /* read capacity command failed */
printk(KERN_WARNING "cciss: read capacity failed\n");
*total_size = 0;
*block_size = BLOCK_SIZE;
}
- if (*total_size != (__u32) 0)
+ if (*total_size != 0)
printk(KERN_INFO " blocks= %llu block_size= %d\n",
- (unsigned long long)*total_size, *block_size);
+ (unsigned long long)*total_size+1, *block_size);
kfree(buf);
return;
}
@@ -1989,7 +1997,7 @@ cciss_read_capacity_16(int ctlr, int logvol, int withirq, sector_t *total_size,
1, logvol, 0, NULL, TYPE_CMD);
}
if (return_code == IO_OK) {
- *total_size = be64_to_cpu(*(__u64 *) buf->total_size)+1;
+ *total_size = be64_to_cpu(*(__u64 *) buf->total_size);
*block_size = be32_to_cpu(*(__u32 *) buf->block_size);
} else { /* read capacity command failed */
printk(KERN_WARNING "cciss: read capacity failed\n");
@@ -1997,7 +2005,7 @@ cciss_read_capacity_16(int ctlr, int logvol, int withirq, sector_t *total_size,
*block_size = BLOCK_SIZE;
}
printk(KERN_INFO " blocks= %llu block_size= %d\n",
- (unsigned long long)*total_size, *block_size);
+ (unsigned long long)*total_size+1, *block_size);
kfree(buf);
return;
}
@@ -3119,8 +3127,9 @@ static void cciss_getgeometry(int cntl_num)
}
cciss_read_capacity(cntl_num, i, 0, &total_size, &block_size);
- /* total_size = last LBA + 1 */
- if(total_size == (__u32) 0) {
+ /* If read_capacity returns all F's the logical is >2TB */
+ /* so we switch to 16-byte CDBs for all read/write ops */
+ if(total_size == 0xFFFFFFFFULL) {
cciss_read_capacity_16(cntl_num, i, 0,
&total_size, &block_size);
hba[cntl_num]->cciss_read = CCISS_READ_16;