pcf50633: get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back into charging mode when the battery voltage falls below 96% of a battery float voltage. The voltage drop in Li-Ion batteries is marginal (1-2%) till about 80% of its capacity - which means, after a BATFULL, charging won't be restarted until 75-80%. That is a desired behaviour recommended by battery manufacturers, don't mess with it. Signed-off-by: Paul Fertser <fercerpav@gmail.com>