diff options
author | Paul Fertser <fercerpav@gmail.com> | 2009-07-29 17:39:52 +0400 |
---|---|---|
committer | Paul Fertser <fercerpav@gmail.com> | 2009-08-02 11:27:19 +0400 |
commit | c31a0fec70c7ab1f9d0a5846abb31b80274e6914 (patch) | |
tree | ae4edf58ac8efabfd3c12b8cfdc07bc14043e894 /include/asm-generic/mm_hooks.h | |
parent | 1ff8185e1564c020b69eff3f222b5393f3b6c35b (diff) |
pcf50633: get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back
into charging mode when the battery voltage falls below 96% of a
battery float voltage. The voltage drop in Li-Ion batteries is
marginal (1-2%) till about 80% of its capacity - which means, after a
BATFULL, charging won't be restarted until 75-80%.
That is a desired behaviour recommended by battery manufacturers,
don't mess with it.
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Diffstat (limited to 'include/asm-generic/mm_hooks.h')
0 files changed, 0 insertions, 0 deletions