diff --git a/drivers/scsi/pmcraid.c b/drivers/scsi/pmcraid.c
index 34c6b896a91..e7d2688fbeb 100644
--- a/drivers/scsi/pmcraid.c
+++ b/drivers/scsi/pmcraid.c
@@ -1,7 +1,8 @@
/*
* pmcraid.c -- driver for PMC Sierra MaxRAID controller adapters
*
- * Written By: PMC Sierra Corporation
+ * Written By: Anil Ravindranath<anil_ravindranath@pmc-sierra.com>
+ * PMC-Sierra Inc
*
* Copyright (C) 2008, 2009 PMC Sierra Inc
*
@@ -79,7 +80,7 @@ DECLARE_BITMAP(pmcraid_minor, PMCRAID_MAX_ADAPTERS);
/*
* Module parameters
*/
-MODULE_AUTHOR("PMC Sierra Corporation, anil_ravindranath@pmc-sierra.com");
+MODULE_AUTHOR("Anil Ravindranath<anil_ravindranath@pmc-sierra.com>");
MODULE_DESCRIPTION("PMC Sierra MaxRAID Controller Driver");
MODULE_LICENSE("GPL");
MODULE_VERSION(PMCRAID_DRIVER_VERSION);
@@ -162,10 +163,10 @@ static int pmcraid_slave_alloc(struct scsi_device *scsi_dev)
spin_lock_irqsave(&pinstance->resource_lock, lock_flags);
list_for_each_entry(temp, &pinstance->used_res_q, queue) {
- /* do not expose VSETs with order-ids >= 240 */
+ /* do not expose VSETs with order-ids > MAX_VSET_TARGETS */
if (RES_IS_VSET(temp->cfg_entry)) {
target = temp->cfg_entry.unique_flags1;
- if (target >= PMCRAID_MAX_VSET_TARGETS)
+ if (target > PMCRAID_MAX_VSET_TARGETS)
continue;
bus = PMCRAID_VSET_BUS_ID;
lun = 0;
@@ -1210,7 +1211,7 @@ static int pmcraid_expose_resource(struct pmcraid_config_table_entry *cfgte)
int retval = 0;
if (cfgte->resource_type == RES_TYPE_VSET)
- retval = ((cfgte->unique_flags1 & 0xFF) < 0xFE);
+ retval = ((cfgte->unique_flags1 & 0x80) == 0);
else if (cfgte->resource_type == RES_TYPE_GSCSI)
retval = (RES_BUS(cfgte->resource_address) !=
PMCRAID_VIRTUAL_ENCL_BUS_ID);
@@ -1361,6 +1362,7 @@ static int pmcraid_notify_aen(struct pmcraid_instance *pinstance, u8 type)
* Return value:
* none
*/
+
static void pmcraid_handle_config_change(struct pmcraid_instance *pinstance)
{
struct pmcraid_config_table_entry *cfg_entry;
@@ -1368,9 +1370,10 @@ static void pmcraid_handle_config_change(struct pmcraid_instance *pinstance)
struct pmcraid_cmd *cmd;
struct pmcraid_cmd *cfgcmd;
struct pmcraid_resource_entry *res = NULL;
- u32 new_entry = 1;
unsigned long lock_flags;
unsigned long host_lock_flags;
+ u32 new_entry = 1;
+ u32 hidden_entry = 0;
int rc;
ccn_hcam = (struct pmcraid_hcam_ccn *)pinstance->ccn.hcam;
@@ -1406,9 +1409,15 @@ static void pmcraid_handle_config_change(struct pmcraid_instance *pinstance)
}
/* If this resource is not going to be added to mid-layer, just notify
- * applications and return
+ * applications and return. If this notification is about hiding a VSET
+ * resource, check if it was exposed already.
*/
- if (!pmcraid_expose_resource(cfg_entry))
+ if (pinstance->ccn.hcam->notification_type ==
+ NOTIFICATION_TYPE_ENTRY_CHANGED &&
+ cfg_entry->resource_type == RES_TYPE_VSET &&
+ cfg_entry->unique_flags1 & 0x80) {
+ hidden_entry = 1;
+ } else if (!pmcraid_expose_resource(cfg_entry))
goto out_notify_apps;
spin_lock_irqsave(&pinstance->resource_lock, lock_flags);
@@ -1424,6 +1433,12 @@ static void pmcraid_handle_config_change(struct pmcraid_instance *pinstance)
if (new_entry) {
+ if (hidden_entry) {
+ spin_unlock_irqrestore(&pinstance->resource_lock,
+ lock_flags);
+ goto out_notify_apps;
+ }
+
/* If there are more number of resources than what driver can
* manage, do not notify the applications about the CCN. Just
* ignore this notifications and re-register the same HCAM
@@ -1454,8 +1469,9 @@ static void pmcraid_handle_config_change(struct pmcraid_instance *pinstance)
sizeof(struct pmcraid_config_table_entry));
if (pinstance->ccn.hcam->notification_type ==
- NOTIFICATION_TYPE_ENTRY_DELETED) {
+ NOTIFICATION_TYPE_ENTRY_DELETED || hidden_entry) {
if (res->scsi_dev) {
+ res->cfg_entry.unique_flags1 &= 0x7F;
res->change_detected = RES_CHANGE_DEL;
res->cfg_entry.resource_handle =
PMCRAID_INVALID_RES_HANDLE;