aboutsummaryrefslogtreecommitdiff
path: root/arch/powerpc/kernel/power6-pmu.c
AgeCommit message (Collapse)Author
2009-06-11perf_counter: Rename L2 to LL cachePeter Zijlstra
The top (fastest) and last level (biggest) caches are the most interesting ones, performance wise. Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Mike Galbraith <efault@gmx.de> Cc: Paul Mackerras <paulus@samba.org> Cc: Arnaldo Carvalho de Melo <acme@redhat.com> LKML-Reference: <new-submission> [ Fixed the Nehalem LL table to LLC Reference/Miss events ] Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-06-11perf_counter: Standardize event namesPeter Zijlstra
Pure renames only, to PERF_COUNT_HW_* and PERF_COUNT_SW_*. Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Mike Galbraith <efault@gmx.de> Cc: Paul Mackerras <paulus@samba.org> Cc: Arnaldo Carvalho de Melo <acme@redhat.com> LKML-Reference: <new-submission> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-06-11perf_counter: powerpc: Implement generalized cache events for POWER processorsPaul Mackerras
This adds tables of event codes for the generalized cache events for all the currently supported powerpc processors: POWER{4,5,5+,6,7} and PPC970*, plus powerpc-specific code to use these tables when a generalized cache event is requested. Signed-off-by: Paul Mackerras <paulus@samba.org> Cc: Peter Zijlstra <a.p.zijlstra@chello.nl> LKML-Reference: <18992.36430.933526.742969@drongo.ozlabs.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-05-15perf_counter: powerpc: supply more precise information on counter overflow ↵Paul Mackerras
events This uses values from the MMCRA, SIAR and SDAR registers on powerpc to supply more precise information for overflow events, including a data address when PERF_RECORD_ADDR is specified. Since POWER6 uses different bit positions in MMCRA from earlier processors, this converts the struct power_pmu limited_pmc5_6 field, which only had 0/1 values, into a flags field and defines bit values for its previous use (PPMU_LIMITED_PMC5_6) and a new flag (PPMU_ALT_SIPR) to indicate that the processor uses the POWER6 bit positions rather than the earlier positions. It also adds definitions in reg.h for the new and old positions of the bit that indicates that the SIAR and SDAR values come from the same instruction. For the data address, the SDAR value is supplied if we are not doing instruction sampling. In that case there is no guarantee that the address given in the PERF_RECORD_ADDR subrecord will correspond to the instruction whose address is given in the PERF_RECORD_IP subrecord. If instruction sampling is enabled (e.g. because this counter is counting a marked instruction event), then we only supply the SDAR value for the PERF_RECORD_ADDR subrecord if it corresponds to the instruction whose address is in the PERF_RECORD_IP subrecord. Otherwise we supply 0. [ Impact: support more PMU hardware features on PowerPC ] Signed-off-by: Paul Mackerras <paulus@samba.org> Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Corey Ashford <cjashfor@linux.vnet.ibm.com> Cc: Arnaldo Carvalho de Melo <acme@redhat.com> LKML-Reference: <18955.37028.48861.555309@drongo.ozlabs.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-05-15perf_counter: powerpc: use u64 for event codes internallyPaul Mackerras
Although the perf_counter API allows 63-bit raw event codes, internally in the powerpc back-end we had been using 32-bit event codes. This expands them to 64 bits so that we can add bits for specifying threshold start/stop events and instruction sampling modes later. This also corrects the return value of can_go_on_limited_pmc; we were returning an event code rather than just a 0/1 value in some circumstances. That didn't particularly matter while event codes were 32-bit, but now that event codes are 64-bit it might, so this fixes it. [ Impact: extend PowerPC perfcounter interfaces from u32 to u64 ] Signed-off-by: Paul Mackerras <paulus@samba.org> Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Corey Ashford <cjashfor@linux.vnet.ibm.com> Cc: Arnaldo Carvalho de Melo <acme@redhat.com> LKML-Reference: <18955.36874.472452.353104@drongo.ozlabs.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-04-29perf_counter: powerpc: allow use of limited-function countersPaul Mackerras
POWER5+ and POWER6 have two hardware counters with limited functionality: PMC5 counts instructions completed in run state and PMC6 counts cycles in run state. (Run state is the state when a hardware RUN bit is 1; the idle task clears RUN while waiting for work to do and sets it when there is work to do.) These counters can't be written to by the kernel, can't generate interrupts, and don't obey the freeze conditions. That means we can only use them for per-task counters (where we know we'll always be in run state; we can't put a per-task counter on an idle task), and only if we don't want interrupts and we do want to count in all processor modes. Obviously some counters can't go on a limited hardware counter, but there are also situations where we can only put a counter on a limited hardware counter - if there are already counters on that exclude some processor modes and we want to put on a per-task cycle or instruction counter that doesn't exclude any processor mode, it could go on if it can use a limited hardware counter. To keep track of these constraints, this adds a flags argument to the processor-specific get_alternatives() functions, with three bits defined: one to say that we can accept alternative event codes that go on limited counters, one to say we only want alternatives on limited counters, and one to say that this is a per-task counter and therefore events that are gated by run state are equivalent to those that aren't (e.g. a "cycles" event is equivalent to a "cycles in run state" event). These flags are computed for each counter and stored in the counter->hw.counter_base field (slightly wonky name for what it does, but it was an existing unused field). Since the limited counters don't freeze when we freeze the other counters, we need some special handling to avoid getting skew between things counted on the limited counters and those counted on normal counters. To minimize this skew, if we are using any limited counters, we read PMC5 and PMC6 immediately after setting and clearing the freeze bit. This is done in a single asm in the new write_mmcr0() function. The code here is specific to PMC5 and PMC6 being the limited hardware counters. Being more general (e.g. having a bitmap of limited hardware counter numbers) would have meant more complex code to read the limited counters when freezing and unfreezing the normal counters, with conditional branches, which would have increased the skew. Since it isn't necessary for the code to be more general at this stage, it isn't. This also extends the back-ends for POWER5+ and POWER6 to be able to handle up to 6 counters rather than the 4 they previously handled. Signed-off-by: Paul Mackerras <paulus@samba.org> Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Cc: Robert Richter <robert.richter@amd.com> LKML-Reference: <18936.19035.163066.892208@cargo.ozlabs.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-04-08perf_counter: powerpc: set sample enable bit for marked instruction eventsPaul Mackerras
Impact: enable access to hardware feature POWER processors have the ability to "mark" a subset of the instructions and provide more detailed information on what happens to the marked instructions as they flow through the pipeline. This marking is enabled by the "sample enable" bit in MMCRA, and there are synchronization requirements around setting and clearing the bit. This adds logic to the processor-specific back-ends so that they know which events relate to marked instructions and set the sampling enable bit if any event that we want to put on the PMU is a marked instruction event. It also adds logic to the generic powerpc code to do the necessary synchronization if that bit is set. Signed-off-by: Paul Mackerras <paulus@samba.org> Cc: Peter Zijlstra <a.p.zijlstra@chello.nl> LKML-Reference: <18908.31930.1024.228867@cargo.ozlabs.ibm.com> Signed-off-by: Ingo Molnar <mingo@elte.hu>
2009-01-10powerpc/perf_counter: Add support for POWER6Paul Mackerras
This adds the back-end for the PMU on the POWER6 processor. Fortunately, the event selection hardware is somewhat simpler on POWER6 than on other POWER family processors, so the constraints fit into only 32 bits. Signed-off-by: Paul Mackerras <paulus@samba.org>