Age | Commit message (Collapse) | Author |
|
The top (fastest) and last level (biggest) caches are the most
interesting ones, performance wise.
Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Mike Galbraith <efault@gmx.de>
Cc: Paul Mackerras <paulus@samba.org>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
LKML-Reference: <new-submission>
[ Fixed the Nehalem LL table to LLC Reference/Miss events ]
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
Pure renames only, to PERF_COUNT_HW_* and PERF_COUNT_SW_*.
Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Mike Galbraith <efault@gmx.de>
Cc: Paul Mackerras <paulus@samba.org>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
LKML-Reference: <new-submission>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
This adds tables of event codes for the generalized cache events for
all the currently supported powerpc processors: POWER{4,5,5+,6,7} and
PPC970*, plus powerpc-specific code to use these tables when a
generalized cache event is requested.
Signed-off-by: Paul Mackerras <paulus@samba.org>
Cc: Peter Zijlstra <a.p.zijlstra@chello.nl>
LKML-Reference: <18992.36430.933526.742969@drongo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
events
This uses values from the MMCRA, SIAR and SDAR registers on
powerpc to supply more precise information for overflow events,
including a data address when PERF_RECORD_ADDR is specified.
Since POWER6 uses different bit positions in MMCRA from earlier
processors, this converts the struct power_pmu limited_pmc5_6
field, which only had 0/1 values, into a flags field and
defines bit values for its previous use (PPMU_LIMITED_PMC5_6)
and a new flag (PPMU_ALT_SIPR) to indicate that the processor
uses the POWER6 bit positions rather than the earlier
positions. It also adds definitions in reg.h for the new and
old positions of the bit that indicates that the SIAR and SDAR
values come from the same instruction.
For the data address, the SDAR value is supplied if we are not
doing instruction sampling. In that case there is no guarantee
that the address given in the PERF_RECORD_ADDR subrecord will
correspond to the instruction whose address is given in the
PERF_RECORD_IP subrecord.
If instruction sampling is enabled (e.g. because this counter
is counting a marked instruction event), then we only supply
the SDAR value for the PERF_RECORD_ADDR subrecord if it
corresponds to the instruction whose address is in the
PERF_RECORD_IP subrecord. Otherwise we supply 0.
[ Impact: support more PMU hardware features on PowerPC ]
Signed-off-by: Paul Mackerras <paulus@samba.org>
Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Corey Ashford <cjashfor@linux.vnet.ibm.com>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
LKML-Reference: <18955.37028.48861.555309@drongo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
Although the perf_counter API allows 63-bit raw event codes,
internally in the powerpc back-end we had been using 32-bit
event codes. This expands them to 64 bits so that we can add
bits for specifying threshold start/stop events and instruction
sampling modes later.
This also corrects the return value of can_go_on_limited_pmc;
we were returning an event code rather than just a 0/1 value in
some circumstances. That didn't particularly matter while event
codes were 32-bit, but now that event codes are 64-bit it
might, so this fixes it.
[ Impact: extend PowerPC perfcounter interfaces from u32 to u64 ]
Signed-off-by: Paul Mackerras <paulus@samba.org>
Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Corey Ashford <cjashfor@linux.vnet.ibm.com>
Cc: Arnaldo Carvalho de Melo <acme@redhat.com>
LKML-Reference: <18955.36874.472452.353104@drongo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
POWER5+ and POWER6 have two hardware counters with limited functionality:
PMC5 counts instructions completed in run state and PMC6 counts cycles
in run state. (Run state is the state when a hardware RUN bit is 1;
the idle task clears RUN while waiting for work to do and sets it when
there is work to do.)
These counters can't be written to by the kernel, can't generate
interrupts, and don't obey the freeze conditions. That means we can
only use them for per-task counters (where we know we'll always be in
run state; we can't put a per-task counter on an idle task), and only
if we don't want interrupts and we do want to count in all processor
modes.
Obviously some counters can't go on a limited hardware counter, but there
are also situations where we can only put a counter on a limited hardware
counter - if there are already counters on that exclude some processor
modes and we want to put on a per-task cycle or instruction counter that
doesn't exclude any processor mode, it could go on if it can use a
limited hardware counter.
To keep track of these constraints, this adds a flags argument to the
processor-specific get_alternatives() functions, with three bits defined:
one to say that we can accept alternative event codes that go on limited
counters, one to say we only want alternatives on limited counters, and
one to say that this is a per-task counter and therefore events that are
gated by run state are equivalent to those that aren't (e.g. a "cycles"
event is equivalent to a "cycles in run state" event). These flags
are computed for each counter and stored in the counter->hw.counter_base
field (slightly wonky name for what it does, but it was an existing
unused field).
Since the limited counters don't freeze when we freeze the other counters,
we need some special handling to avoid getting skew between things counted
on the limited counters and those counted on normal counters. To minimize
this skew, if we are using any limited counters, we read PMC5 and PMC6
immediately after setting and clearing the freeze bit. This is done in
a single asm in the new write_mmcr0() function.
The code here is specific to PMC5 and PMC6 being the limited hardware
counters. Being more general (e.g. having a bitmap of limited hardware
counter numbers) would have meant more complex code to read the limited
counters when freezing and unfreezing the normal counters, with
conditional branches, which would have increased the skew. Since it
isn't necessary for the code to be more general at this stage, it isn't.
This also extends the back-ends for POWER5+ and POWER6 to be able to
handle up to 6 counters rather than the 4 they previously handled.
Signed-off-by: Paul Mackerras <paulus@samba.org>
Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Cc: Robert Richter <robert.richter@amd.com>
LKML-Reference: <18936.19035.163066.892208@cargo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
Impact: enable access to hardware feature
POWER processors have the ability to "mark" a subset of the instructions
and provide more detailed information on what happens to the marked
instructions as they flow through the pipeline. This marking is
enabled by the "sample enable" bit in MMCRA, and there are
synchronization requirements around setting and clearing the bit.
This adds logic to the processor-specific back-ends so that they know
which events relate to marked instructions and set the sampling enable
bit if any event that we want to put on the PMU is a marked instruction
event. It also adds logic to the generic powerpc code to do the
necessary synchronization if that bit is set.
Signed-off-by: Paul Mackerras <paulus@samba.org>
Cc: Peter Zijlstra <a.p.zijlstra@chello.nl>
LKML-Reference: <18908.31930.1024.228867@cargo.ozlabs.ibm.com>
Signed-off-by: Ingo Molnar <mingo@elte.hu>
|
|
This adds the back-end for the PMU on the POWER6 processor.
Fortunately, the event selection hardware is somewhat simpler on
POWER6 than on other POWER family processors, so the constraints
fit into only 32 bits.
Signed-off-by: Paul Mackerras <paulus@samba.org>
|