From 87aa63000c484bfb9909989316f615240dfee018 Mon Sep 17 00:00:00 2001 From: "Gabriele A. Trombetti" Date: Wed, 28 Apr 2010 11:51:17 +1000 Subject: md/raid6: Fix raid-6 read-error correction in degraded state Fix: Raid-6 was not trying to correct a read-error when in singly-degraded state and was instead dropping one more device, going to doubly-degraded state. This patch fixes this behaviour. Tested-by: Janos Haar Signed-off-by: Gabriele A. Trombetti Reported-by: Janos Haar Signed-off-by: NeilBrown Cc: stable@kernel.org --- drivers/md/raid5.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index 58ea0ecae7c..15348c393b5 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -1527,7 +1527,7 @@ static void raid5_end_read_request(struct bio * bi, int error) clear_bit(R5_UPTODATE, &sh->dev[i].flags); atomic_inc(&rdev->read_errors); - if (conf->mddev->degraded) + if (conf->mddev->degraded >= conf->max_degraded) printk_rl(KERN_WARNING "raid5:%s: read error not correctable " "(sector %llu on %s).\n", -- cgit v1.2.3