From f3be97427172856d6865ddfedea84fa3a9f33227 Mon Sep 17 00:00:00 2001 From: Andrew Morton Date: Tue, 6 Mar 2007 02:41:55 -0800 Subject: sis900 warning fixes drivers/net/sis900.c: In function 'sis900_reset_phy': drivers/net/sis900.c:972: warning: 'status' may be used uninitialized in this function drivers/net/sis900.c: In function 'sis900_check_mode': drivers/net/sis900.c:1431: warning: 'status' may be used uninitialized in this function drivers/net/sis900.c: In function 'sis900_timer': drivers/net/sis900.c:1467: warning: 'status' may be used uninitialized in this function Signed-off-by: Andrew Morton Signed-off-by: Jeff Garzik --- drivers/net/sis900.c | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-) diff --git a/drivers/net/sis900.c b/drivers/net/sis900.c index fb2b5305163..b3750f28427 100644 --- a/drivers/net/sis900.c +++ b/drivers/net/sis900.c @@ -968,10 +968,10 @@ static void mdio_write(struct net_device *net_dev, int phy_id, int location, static u16 sis900_reset_phy(struct net_device *net_dev, int phy_addr) { - int i = 0; + int i; u16 status; - while (i++ < 2) + for (i = 0; i < 2; i++) status = mdio_read(net_dev, phy_addr, MII_STATUS); mdio_write( net_dev, phy_addr, MII_CONTROL, MII_CNTL_RESET ); @@ -1430,7 +1430,7 @@ static void sis900_auto_negotiate(struct net_device *net_dev, int phy_addr) int i = 0; u32 status; - while (i++ < 2) + for (i = 0; i < 2; i++) status = mdio_read(net_dev, phy_addr, MII_STATUS); if (!(status & MII_STAT_LINK)){ @@ -1466,9 +1466,9 @@ static void sis900_read_mode(struct net_device *net_dev, int *speed, int *duplex int phy_addr = sis_priv->cur_phy; u32 status; u16 autoadv, autorec; - int i = 0; + int i; - while (i++ < 2) + for (i = 0; i < 2; i++) status = mdio_read(net_dev, phy_addr, MII_STATUS); if (!(status & MII_STAT_LINK)) -- cgit v1.2.3