From ad02ad85cf221c9a0574b48516762e37cceca0da Mon Sep 17 00:00:00 2001 From: Marc Hulsman Date: Wed, 6 Aug 2008 22:41:04 +0200 Subject: hwmon: (w83791d) Use fan divisor bits from vbat register Update w83791d with fan bits in vbat mon register (7.48 of the datasheet). This change allows all fans to have a divisor of 128, and fixes a problem with incorrectly reported fan speeds. Signed-off-by: Marc Hulsman Signed-off-by: Jean Delvare --- Documentation/hwmon/w83791d | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) (limited to 'Documentation/hwmon') diff --git a/Documentation/hwmon/w83791d b/Documentation/hwmon/w83791d index f153b2f6d62..a67d3b7a709 100644 --- a/Documentation/hwmon/w83791d +++ b/Documentation/hwmon/w83791d @@ -22,6 +22,7 @@ Credits: Additional contributors: Sven Anders + Marc Hulsman Module Parameters ----------------- @@ -67,9 +68,8 @@ on until the temperature falls below the Hysteresis value. Fan rotation speeds are reported in RPM (rotations per minute). An alarm is triggered if the rotation speed has dropped below a programmable limit. Fan -readings can be divided by a programmable divider (1, 2, 4, 8 for fan 1/2/3 -and 1, 2, 4, 8, 16, 32, 64 or 128 for fan 4/5) to give the readings more -range or accuracy. +readings can be divided by a programmable divider (1, 2, 4, 8, 16, +32, 64 or 128 for all fans) to give the readings more range or accuracy. Voltage sensors (also known as IN sensors) report their values in millivolts. An alarm is triggered if the voltage has crossed a programmable minimum -- cgit v1.2.3