From 98714cb161b4b1a5d0c5bd0337a8578196b73677 Mon Sep 17 00:00:00 2001 From: Jack Morgenstein Date: Mon, 25 Dec 2006 09:24:52 +0200 Subject: IB/mthca: Fix PRM compliance problem in atomic-send completions According to the Tavor and Arbel programmer's reference manuals, the number of bytes transferred is not provided in the byte_cnt field of the CQ entry for atomic operation completions. For atomic operations, the number of bytes transferred is always 8 (when the status is "success"), and this constant value should always be used by the driver in the ib_wc entry returned, rather than using the CQE. Signed-off-by: Jack Morgenstein Signed-off-by: Roland Dreier --- drivers/infiniband/hw/mthca/mthca_cq.c | 8 ++++++-- 1 file changed, 6 insertions(+), 2 deletions(-) (limited to 'drivers/infiniband/hw') diff --git a/drivers/infiniband/hw/mthca/mthca_cq.c b/drivers/infiniband/hw/mthca/mthca_cq.c index 283d50b76c3..1159c8a0f2c 100644 --- a/drivers/infiniband/hw/mthca/mthca_cq.c +++ b/drivers/infiniband/hw/mthca/mthca_cq.c @@ -54,6 +54,10 @@ enum { MTHCA_CQ_ENTRY_SIZE = 0x20 }; +enum { + MTHCA_ATOMIC_BYTE_LEN = 8 +}; + /* * Must be packed because start is 64 bits but only aligned to 32 bits. */ @@ -599,11 +603,11 @@ static inline int mthca_poll_one(struct mthca_dev *dev, break; case MTHCA_OPCODE_ATOMIC_CS: entry->opcode = IB_WC_COMP_SWAP; - entry->byte_len = be32_to_cpu(cqe->byte_cnt); + entry->byte_len = MTHCA_ATOMIC_BYTE_LEN; break; case MTHCA_OPCODE_ATOMIC_FA: entry->opcode = IB_WC_FETCH_ADD; - entry->byte_len = be32_to_cpu(cqe->byte_cnt); + entry->byte_len = MTHCA_ATOMIC_BYTE_LEN; break; case MTHCA_OPCODE_BIND_MW: entry->opcode = IB_WC_BIND_MW; -- cgit v1.2.3