diff options
author | Paul Fertser <fercerpav@gmail.com> | 2009-07-29 17:39:52 +0400 |
---|---|---|
committer | Lars-Peter Clausen <lars@metafoo.de> | 2009-12-06 09:09:22 +0100 |
commit | 08e4c1d585561d59cf2fa428b2df8d6c185e3af9 (patch) | |
tree | 72758ca4da540265a4b46bf33fd09fe94cdbe2ff /.mailmap | |
parent | b7f9bc73c7abc0de20081739fc990e92f5bccfc6 (diff) |
power: pcf50633: get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back
into charging mode when the battery voltage falls below 96% of a
battery float voltage. The voltage drop in Li-Ion batteries is
marginal (1-2%) till about 80% of its capacity - which means, after a
BATFULL, charging won't be restarted until 75-80%.
That is a desired behaviour recommended by battery manufacturers,
don't mess with it.
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Diffstat (limited to '.mailmap')
0 files changed, 0 insertions, 0 deletions