aboutsummaryrefslogtreecommitdiff
path: root/drivers/staging/panel/Kconfig
diff options
context:
space:
mode:
authorDavid Vrabel <david.vrabel@csr.com>2009-01-07 10:45:25 +0000
committerDavid Vrabel <david.vrabel@csr.com>2009-01-07 10:45:25 +0000
commita23e66f3b8cfdedec14541e71ef29a754870a20c (patch)
treef8ac23572982e92e6f8ae09c4039db627bdf53ee /drivers/staging/panel/Kconfig
parent04c470adb01c62bb9bd663cfc4875cf0a4eb01ab (diff)
parentede6f5aea054d3fb67c78857f7abdee602302043 (diff)
Merge branch 'master' of git://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux-2.6 into for-upstream
Diffstat (limited to 'drivers/staging/panel/Kconfig')
-rw-r--r--drivers/staging/panel/Kconfig278
1 files changed, 278 insertions, 0 deletions
diff --git a/drivers/staging/panel/Kconfig b/drivers/staging/panel/Kconfig
new file mode 100644
index 00000000000..c4b30f2a549
--- /dev/null
+++ b/drivers/staging/panel/Kconfig
@@ -0,0 +1,278 @@
+config PANEL
+ tristate "Parallel port LCD/Keypad Panel support"
+ depends on PARPORT
+ ---help---
+ Say Y here if you have an HD44780 or KS-0074 LCD connected to your
+ parallel port. This driver also features 4 and 6-key keypads. The LCD
+ is accessible through the /dev/lcd char device (10, 156), and the
+ keypad through /dev/keypad (10, 185). Both require misc device to be
+ enabled. This code can either be compiled as a module, or linked into
+ the kernel and started at boot. If you don't understand what all this
+ is about, say N.
+
+config PANEL_PARPORT
+ int "Default parallel port number (0=LPT1)"
+ depends on PANEL
+ range 0 255
+ default "0"
+ ---help---
+ This is the index of the parallel port the panel is connected to. One
+ driver instance only supports one parallel port, so if your keypad
+ and LCD are connected to two separate ports, you have to start two
+ modules with different arguments. Numbering starts with '0' for LPT1,
+ and so on.
+
+config PANEL_PROFILE
+ int "Default panel profile (0-5, 0=custom)"
+ depends on PANEL
+ range 0 5
+ default "5"
+ ---help---
+ To ease configuration, the driver supports different configuration
+ profiles for past and recent wirings. These profiles can also be
+ used to define an approximative configuration, completed by a few
+ other options. Here are the profiles :
+
+ 0 = custom (see further)
+ 1 = 2x16 parallel LCD, old keypad
+ 2 = 2x16 serial LCD (KS-0074), new keypad
+ 3 = 2x16 parallel LCD (Hantronix), no keypad
+ 4 = 2x16 parallel LCD (Nexcom NSA1045) with Nexcom's keypad
+ 5 = 2x40 parallel LCD (old one), with old keypad
+
+ Custom configurations allow you to define how your display is
+ wired to the parallel port, and how it works. This is only intended
+ for experts.
+
+config PANEL_KEYPAD
+ depends on PANEL && PANEL_PROFILE="0"
+ int "Keypad type (0=none, 1=old 6 keys, 2=new 6 keys, 3=Nexcom 4 keys)"
+ range 0 4
+ default 0
+ ---help---
+ This enables and configures a keypad connected to the parallel port.
+ The keys will be read from character device 10,185. Valid values are :
+
+ 0 : do not enable this driver
+ 1 : old 6 keys keypad
+ 2 : new 6 keys keypad, as used on the server at www.ant-computing.com
+ 3 : Nexcom NSA1045's 4 keys keypad
+
+ New profiles can be described in the driver source. The driver also
+ supports simultaneous keys pressed when the keypad supports them.
+
+config PANEL_LCD
+ depends on PANEL && PANEL_PROFILE="0"
+ int "LCD type (0=none, 1=custom, 2=old //, 3=ks0074, 4=hantronix, 5=Nexcom)"
+ range 0 5
+ default 0
+ ---help---
+ This enables and configures an LCD connected to the parallel port.
+ The driver includes an interpreter for escape codes starting with
+ '\e[L' which are specific to the LCD, and a few ANSI codes. The
+ driver will be registered as character device 10,156, usually
+ under the name '/dev/lcd'. There are a total of 6 supported types :
+
+ 0 : do not enable the driver
+ 1 : custom configuration and wiring (see further)
+ 2 : 2x16 & 2x40 parallel LCD (old wiring)
+ 3 : 2x16 serial LCD (KS-0074 based)
+ 4 : 2x16 parallel LCD (Hantronix wiring)
+ 5 : 2x16 parallel LCD (Nexcom wiring)
+
+ When type '1' is specified, other options will appear to configure
+ more precise aspects (wiring, dimensions, protocol, ...). Please note
+ that those values changed from the 2.4 driver for better consistency.
+
+config PANEL_LCD_HEIGHT
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "Number of lines on the LCD (1-2)"
+ range 1 2
+ default 2
+ ---help---
+ This is the number of visible character lines on the LCD in custom profile.
+ It can either be 1 or 2.
+
+config PANEL_LCD_WIDTH
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "Number of characters per line on the LCD (1-40)"
+ range 1 40
+ default 40
+ ---help---
+ This is the number of characters per line on the LCD in custom profile.
+ Common values are 16,20,24,40.
+
+config PANEL_LCD_BWIDTH
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "Internal LCD line width (1-40, 40 by default)"
+ range 1 40
+ default 40
+ ---help---
+ Most LCDs use a standard controller which supports hardware lines of 40
+ characters, although sometimes only 16, 20 or 24 of them are really wired
+ to the terminal. This results in some non-visible but adressable characters,
+ and is the case for most parallel LCDs. Other LCDs, and some serial ones,
+ however, use the same line width internally as what is visible. The KS0074
+ for example, uses 16 characters per line for 16 visible characters per line.
+
+ This option lets you configure the value used by your LCD in 'custom' profile.
+ If you don't know, put '40' here.
+
+config PANEL_LCD_HWIDTH
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "Hardware LCD line width (1-64, 64 by default)"
+ range 1 64
+ default 64
+ ---help---
+ Most LCDs use a single address bit to differentiate line 0 and line 1. Since
+ some of them need to be able to address 40 chars with the lower bits, they
+ often use the immediately superior power of 2, which is 64, to address the
+ next line.
+
+ If you don't know what your LCD uses, in doubt let 16 here for a 2x16, and
+ 64 here for a 2x40.
+
+config PANEL_LCD_CHARSET
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "LCD character set (0=normal, 1=KS0074)"
+ range 0 1
+ default 0
+ ---help---
+ Some controllers such as the KS0074 use a somewhat strange character set
+ where many symbols are at unusual places. The driver knows how to map
+ 'standard' ASCII characters to the character sets used by these controllers.
+ Valid values are :
+
+ 0 : normal (untranslated) character set
+ 1 : KS0074 character set
+
+ If you don't know, use the normal one (0).
+
+config PANEL_LCD_PROTO
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "LCD communication mode (0=parallel 8 bits, 1=serial)"
+ range 0 1
+ default 0
+ ---help---
+ This driver now supports any serial or parallel LCD wired to a parallel
+ port. But before assigning signals, the driver needs to know if it will
+ be driving a serial LCD or a parallel one. Serial LCDs only use 2 wires
+ (SDA/SCL), while parallel ones use 2 or 3 wires for the control signals
+ (E, RS, sometimes RW), and 4 or 8 for the data. Use 0 here for a 8 bits
+ parallel LCD, and 1 for a serial LCD.
+
+config PANEL_LCD_PIN_E
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
+ int "Parallel port pin number & polarity connected to the LCD E signal (-17...17) "
+ range -17 17
+ default 14
+ ---help---
+ This describes the number of the parallel port pin to which the LCD 'E'
+ signal has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'E' pin in custom profile is '14' (AUTOFEED).
+
+config PANEL_LCD_PIN_RS
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
+ int "Parallel port pin number & polarity connected to the LCD RS signal (-17...17) "
+ range -17 17
+ default 17
+ ---help---
+ This describes the number of the parallel port pin to which the LCD 'RS'
+ signal has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'RS' pin in custom profile is '17' (SELECT IN).
+
+config PANEL_LCD_PIN_RW
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO="0"
+ int "Parallel port pin number & polarity connected to the LCD RW signal (-17...17) "
+ range -17 17
+ default 16
+ ---help---
+ This describes the number of the parallel port pin to which the LCD 'RW'
+ signal has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'RW' pin in custom profile is '16' (INIT).
+
+config PANEL_LCD_PIN_SCL
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
+ int "Parallel port pin number & polarity connected to the LCD SCL signal (-17...17) "
+ range -17 17
+ default 1
+ ---help---
+ This describes the number of the parallel port pin to which the serial
+ LCD 'SCL' signal has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'SCL' pin in custom profile is '1' (STROBE).
+
+config PANEL_LCD_PIN_SDA
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1" && PANEL_LCD_PROTO!="0"
+ int "Parallel port pin number & polarity connected to the LCD SDA signal (-17...17) "
+ range -17 17
+ default 2
+ ---help---
+ This describes the number of the parallel port pin to which the serial
+ LCD 'SDA' signal has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'SDA' pin in custom profile is '2' (D0).
+
+config PANEL_LCD_PIN_BL
+ depends on PANEL && PANEL_PROFILE="0" && PANEL_LCD="1"
+ int "Parallel port pin number & polarity connected to the LCD backlight signal (-17...17) "
+ range -17 17
+ default 0
+ ---help---
+ This describes the number of the parallel port pin to which the LCD 'BL' signal
+ has been connected. It can be :
+
+ 0 : no connection (eg: connected to ground)
+ 1..17 : directly connected to any of these pins on the DB25 plug
+ -1..-17 : connected to the same pin through an inverter (eg: transistor).
+
+ Default for the 'BL' pin in custom profile is '0' (uncontrolled).
+
+config PANEL_CHANGE_MESSAGE
+ depends on PANEL
+ bool "Change LCD initialization message ?"
+ default "n"
+ ---help---
+ This allows you to replace the boot message indicating the kernel version
+ and the driver version with a custom message. This is useful on appliances
+ where a simple 'Starting system' message can be enough to stop a customer
+ from worrying.
+
+ If you say 'Y' here, you'll be able to choose a message yourself. Otherwise,
+ say 'N' and keep the default message with the version.
+
+config PANEL_BOOT_MESSAGE
+ depends on PANEL && PANEL_CHANGE_MESSAGE="y"
+ string "New initialization message"
+ default ""
+ ---help---
+ This allows you to replace the boot message indicating the kernel version
+ and the driver version with a custom message. This is useful on appliances
+ where a simple 'Starting system' message can be enough to stop a customer
+ from worrying.
+
+ An empty message will only clear the display at driver init time. Any other
+ printf()-formatted message is valid with newline and escape codes.