pcf50633: get rid of charging restart software auto-triggering
After reaching Battery Full condition MBC state machine switches back into charging mode when the battery voltage falls below 96% of a battery float voltage. The voltage drop in Li-Ion batteries is marginal (1-2%) till about 80% of its capacity - which means, after a BATFULL, charging won't be restarted until 75-80%. That is a desired behaviour recommended by battery manufacturers, don't mess with it. Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Diffstat (limited to 'include/linux')
-rw-r--r--include/linux/mfd/pcf50633/core.h2
1 files changed, 0 insertions, 2 deletions
diff --git a/include/linux/mfd/pcf50633/core.h b/include/linux/mfd/pcf50633/core.h
index aed1fabb068..c8125f2e99e 100644
--- a/include/linux/mfd/pcf50633/core.h
+++ b/include/linux/mfd/pcf50633/core.h
@@ -29,8 +29,6 @@ struct pcf50633_platform_data {
char **batteries;
int num_batteries;
- int charging_restart_interval;
-
int chg_ref_current_ma;
/* Callbacks */