diff options
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/power/power_supply_class.txt | 7 |
1 files changed, 7 insertions, 0 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index c6cd4956047..9f16c5178b6 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -76,6 +76,11 @@ STATUS - this attribute represents operating status (charging, full, discharging (i.e. powering a load), etc.). This corresponds to BATTERY_STATUS_* values, as defined in battery.h. +CHARGE_TYPE - batteries can typically charge at different rates. +This defines trickle and fast charges. For batteries that +are already charged or discharging, 'n/a' can be displayed (or +'unknown', if the status is not known). + HEALTH - represents health of the battery, values corresponds to POWER_SUPPLY_HEALTH_*, defined in battery.h. @@ -108,6 +113,8 @@ relative, time-based measurements. ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents. +CAPACITY_LEVEL - capacity level. This corresponds to +POWER_SUPPLY_CAPACITY_LEVEL_*. TEMP - temperature of the power supply. TEMP_AMBIENT - ambient temperature. |