aboutsummaryrefslogtreecommitdiff
path: root/arch/arm/mach-s3c2410/Kconfig
diff options
context:
space:
mode:
Diffstat (limited to 'arch/arm/mach-s3c2410/Kconfig')
-rw-r--r--arch/arm/mach-s3c2410/Kconfig29
1 files changed, 20 insertions, 9 deletions
diff --git a/arch/arm/mach-s3c2410/Kconfig b/arch/arm/mach-s3c2410/Kconfig
index 63965c78de8..eb4ec411312 100644
--- a/arch/arm/mach-s3c2410/Kconfig
+++ b/arch/arm/mach-s3c2410/Kconfig
@@ -5,6 +5,7 @@ menu "S3C24XX Implementations"
config MACH_AML_M5900
bool "AML M5900 Series"
select CPU_S3C2410
+ select PM_SIMTEC if PM
help
Say Y here if you are using the American Microsystems M5900 Series
<http://www.amltd.com>
@@ -12,6 +13,7 @@ config MACH_AML_M5900
config MACH_ANUBIS
bool "Simtec Electronics ANUBIS"
select CPU_S3C2440
+ select PM_SIMTEC if PM
help
Say Y here if you are using the Simtec Electronics ANUBIS
development system
@@ -19,6 +21,7 @@ config MACH_ANUBIS
config MACH_OSIRIS
bool "Simtec IM2440D20 (OSIRIS) module"
select CPU_S3C2440
+ select PM_SIMTEC if PM
help
Say Y here if you are using the Simtec IM2440D20 module, also
known as the Osiris.
@@ -26,6 +29,7 @@ config MACH_OSIRIS
config ARCH_BAST
bool "Simtec Electronics BAST (EB2410ITX)"
select CPU_S3C2410
+ select PM_SIMTEC if PM
select ISA
help
Say Y here if you are using the Simtec Electronics EB2410ITX
@@ -41,9 +45,15 @@ config BAST_PC104_IRQ
Say Y here to enable the PC104 IRQ routing on the
Simtec BAST (EB2410ITX)
+config PM_H1940
+ bool
+ help
+ Internal node for H1940 and related PM
+
config ARCH_H1940
bool "IPAQ H1940"
select CPU_S3C2410
+ select PM_H1940 if PM
help
Say Y here if you are using the HP IPAQ H1940
@@ -91,7 +101,7 @@ config SMDK2440_CPU2442
config MACH_S3C2413
bool
help
- Internal node for S3C2413 verison of SMDK2413, so that
+ Internal node for S3C2413 version of SMDK2413, so that
machine_is_s3c2413() will work when MACH_SMDK2413 is
selected
@@ -105,6 +115,7 @@ config MACH_SMDK2413
config MACH_VR1000
bool "Thorcom VR1000"
+ select PM_SIMTEC if PM
select CPU_S3C2410
help
Say Y here if you are using the Thorcom VR1000 board.
@@ -115,6 +126,7 @@ config MACH_VR1000
config MACH_RX3715
bool "HP iPAQ rx3715"
select CPU_S3C2440
+ select PM_H1940 if PM
help
Say Y here if you are using the HP iPAQ rx3715.
@@ -148,7 +160,6 @@ config S3C2410_CLOCK
config S3C2410_PM
bool
- depends on CONFIG_PM
help
Power Management code common to S3C2410 and better
@@ -163,7 +174,7 @@ config CPU_S3C2410
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
help
Support for S3C2410 and S3C2410A family from the S3C24XX line
of Samsung Mobile CPUs.
@@ -178,14 +189,13 @@ config CPU_S3C2412_ONLY
config S3C2412_PM
bool
- default y if PM
- depends on CPU_S3C2412
help
Internal config node to apply S3C2412 power management
config CPU_S3C2412
bool
depends on ARCH_S3C2410
+ select S3C2412_PM if PM
help
Support for the S3C2412 and S3C2413 SoCs from the S3C24XX line
@@ -199,7 +209,7 @@ config CPU_S3C2440
bool
depends on ARCH_S3C2410
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2440 Samsung Mobile CPU based systems.
@@ -208,7 +218,7 @@ config CPU_S3C2442
bool
depends on ARCH_S3C2420
select S3C2410_CLOCK
- select S3C2410_PM
+ select S3C2410_PM if PM
select CPU_S3C244X
help
Support for S3C2442 Samsung Mobile CPU based systems.
@@ -292,8 +302,9 @@ config S3C2410_PM_CHECK_CHUNKSIZE
config PM_SIMTEC
bool
- depends on PM && (ARCH_BAST || MACH_VR1000 || MACH_AML_M5900)
- default y
+ help
+ Common power management code for systems that are
+ compatible with the Simtec style of power management
config S3C2410_LOWLEVEL_UART_PORT
int "S3C2410 UART to use for low-level messages"