aboutsummaryrefslogtreecommitdiff
path: root/drivers/power/olpc_battery.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/power/olpc_battery.c')
-rw-r--r--drivers/power/olpc_battery.c273
1 files changed, 197 insertions, 76 deletions
diff --git a/drivers/power/olpc_battery.c b/drivers/power/olpc_battery.c
index ab1e8289f07..32570af3c5c 100644
--- a/drivers/power/olpc_battery.c
+++ b/drivers/power/olpc_battery.c
@@ -19,7 +19,7 @@
#define EC_BAT_VOLTAGE 0x10 /* uint16_t, *9.76/32, mV */
#define EC_BAT_CURRENT 0x11 /* int16_t, *15.625/120, mA */
-#define EC_BAT_ACR 0x12
+#define EC_BAT_ACR 0x12 /* int16_t, *6250/15, µAh */
#define EC_BAT_TEMP 0x13 /* uint16_t, *100/256, °C */
#define EC_AMB_TEMP 0x14 /* uint16_t, *100/256, °C */
#define EC_BAT_STATUS 0x15 /* uint8_t, bitmask */
@@ -84,6 +84,119 @@ static struct power_supply olpc_ac = {
.get_property = olpc_ac_get_prop,
};
+static char bat_serial[17]; /* Ick */
+
+static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
+{
+ if (olpc_platform_info.ecver > 0x44) {
+ if (ec_byte & BAT_STAT_CHARGING)
+ val->intval = POWER_SUPPLY_STATUS_CHARGING;
+ else if (ec_byte & BAT_STAT_DISCHARGING)
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ else if (ec_byte & BAT_STAT_FULL)
+ val->intval = POWER_SUPPLY_STATUS_FULL;
+ else /* er,... */
+ val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
+ } else {
+ /* Older EC didn't report charge/discharge bits */
+ if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ else if (ec_byte & BAT_STAT_FULL)
+ val->intval = POWER_SUPPLY_STATUS_FULL;
+ else /* Not _necessarily_ true but EC doesn't tell all yet */
+ val->intval = POWER_SUPPLY_STATUS_CHARGING;
+ }
+
+ return 0;
+}
+
+static int olpc_bat_get_health(union power_supply_propval *val)
+{
+ uint8_t ec_byte;
+ int ret;
+
+ ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+ if (ret)
+ return ret;
+
+ switch (ec_byte) {
+ case 0:
+ val->intval = POWER_SUPPLY_HEALTH_GOOD;
+ break;
+
+ case BAT_ERR_OVERTEMP:
+ val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+ break;
+
+ case BAT_ERR_OVERVOLTAGE:
+ val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
+ break;
+
+ case BAT_ERR_INFOFAIL:
+ case BAT_ERR_OUT_OF_CONTROL:
+ case BAT_ERR_ID_FAIL:
+ case BAT_ERR_ACR_FAIL:
+ val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
+ break;
+
+ default:
+ /* Eep. We don't know this failure code */
+ ret = -EIO;
+ }
+
+ return ret;
+}
+
+static int olpc_bat_get_mfr(union power_supply_propval *val)
+{
+ uint8_t ec_byte;
+ int ret;
+
+ ec_byte = BAT_ADDR_MFR_TYPE;
+ ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+ if (ret)
+ return ret;
+
+ switch (ec_byte >> 4) {
+ case 1:
+ val->strval = "Gold Peak";
+ break;
+ case 2:
+ val->strval = "BYD";
+ break;
+ default:
+ val->strval = "Unknown";
+ break;
+ }
+
+ return ret;
+}
+
+static int olpc_bat_get_tech(union power_supply_propval *val)
+{
+ uint8_t ec_byte;
+ int ret;
+
+ ec_byte = BAT_ADDR_MFR_TYPE;
+ ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+ if (ret)
+ return ret;
+
+ switch (ec_byte & 0xf) {
+ case 1:
+ val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
+ break;
+ case 2:
+ val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
+ break;
+ default:
+ val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
+ break;
+ }
+
+ return ret;
+}
+
/*********************************************************************
* Battery properties
*********************************************************************/
@@ -94,6 +207,7 @@ static int olpc_bat_get_property(struct power_supply *psy,
int ret = 0;
int16_t ec_word;
uint8_t ec_byte;
+ uint64_t ser_buf;
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1);
if (ret)
@@ -110,25 +224,10 @@ static int olpc_bat_get_property(struct power_supply *psy,
switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
- if (olpc_platform_info.ecver > 0x44) {
- if (ec_byte & BAT_STAT_CHARGING)
- val->intval = POWER_SUPPLY_STATUS_CHARGING;
- else if (ec_byte & BAT_STAT_DISCHARGING)
- val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
- else if (ec_byte & BAT_STAT_FULL)
- val->intval = POWER_SUPPLY_STATUS_FULL;
- else /* er,... */
- val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
- } else {
- /* Older EC didn't report charge/discharge bits */
- if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
- val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
- else if (ec_byte & BAT_STAT_FULL)
- val->intval = POWER_SUPPLY_STATUS_FULL;
- else /* Not _necessarily_ true but EC doesn't tell all yet */
- val->intval = POWER_SUPPLY_STATUS_CHARGING;
- break;
- }
+ ret = olpc_bat_get_status(val, ec_byte);
+ if (ret)
+ return ret;
+ break;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
break;
@@ -137,72 +236,21 @@ static int olpc_bat_get_property(struct power_supply *psy,
if (ec_byte & BAT_STAT_DESTROY)
val->intval = POWER_SUPPLY_HEALTH_DEAD;
else {
- ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
+ ret = olpc_bat_get_health(val);
if (ret)
return ret;
-
- switch (ec_byte) {
- case 0:
- val->intval = POWER_SUPPLY_HEALTH_GOOD;
- break;
-
- case BAT_ERR_OVERTEMP:
- val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
- break;
-
- case BAT_ERR_OVERVOLTAGE:
- val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
- break;
-
- case BAT_ERR_INFOFAIL:
- case BAT_ERR_OUT_OF_CONTROL:
- case BAT_ERR_ID_FAIL:
- case BAT_ERR_ACR_FAIL:
- val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
- break;
-
- default:
- /* Eep. We don't know this failure code */
- return -EIO;
- }
}
break;
case POWER_SUPPLY_PROP_MANUFACTURER:
- ec_byte = BAT_ADDR_MFR_TYPE;
- ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+ ret = olpc_bat_get_mfr(val);
if (ret)
return ret;
-
- switch (ec_byte >> 4) {
- case 1:
- val->strval = "Gold Peak";
- break;
- case 2:
- val->strval = "BYD";
- break;
- default:
- val->strval = "Unknown";
- break;
- }
break;
case POWER_SUPPLY_PROP_TECHNOLOGY:
- ec_byte = BAT_ADDR_MFR_TYPE;
- ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
+ ret = olpc_bat_get_tech(val);
if (ret)
return ret;
-
- switch (ec_byte & 0xf) {
- case 1:
- val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
- break;
- case 2:
- val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
- break;
- default:
- val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
- break;
- }
break;
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);
@@ -241,6 +289,22 @@ static int olpc_bat_get_property(struct power_supply *psy,
ec_word = be16_to_cpu(ec_word);
val->intval = ec_word * 100 / 256;
break;
+ case POWER_SUPPLY_PROP_CHARGE_COUNTER:
+ ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2);
+ if (ret)
+ return ret;
+
+ ec_word = be16_to_cpu(ec_word);
+ val->intval = ec_word * 6250 / 15;
+ break;
+ case POWER_SUPPLY_PROP_SERIAL_NUMBER:
+ ret = olpc_ec_cmd(EC_BAT_SERIAL, NULL, 0, (void *)&ser_buf, 8);
+ if (ret)
+ return ret;
+
+ sprintf(bat_serial, "%016llx", (long long)be64_to_cpu(ser_buf));
+ val->strval = bat_serial;
+ break;
default:
ret = -EINVAL;
break;
@@ -260,6 +324,50 @@ static enum power_supply_property olpc_bat_props[] = {
POWER_SUPPLY_PROP_TEMP,
POWER_SUPPLY_PROP_TEMP_AMBIENT,
POWER_SUPPLY_PROP_MANUFACTURER,
+ POWER_SUPPLY_PROP_SERIAL_NUMBER,
+ POWER_SUPPLY_PROP_CHARGE_COUNTER,
+};
+
+/* EEPROM reading goes completely around the power_supply API, sadly */
+
+#define EEPROM_START 0x20
+#define EEPROM_END 0x80
+#define EEPROM_SIZE (EEPROM_END - EEPROM_START)
+
+static ssize_t olpc_bat_eeprom_read(struct kobject *kobj,
+ struct bin_attribute *attr, char *buf, loff_t off, size_t count)
+{
+ uint8_t ec_byte;
+ int ret, end;
+
+ if (off >= EEPROM_SIZE)
+ return 0;
+ if (off + count > EEPROM_SIZE)
+ count = EEPROM_SIZE - off;
+
+ end = EEPROM_START + off + count;
+ for (ec_byte = EEPROM_START + off; ec_byte < end; ec_byte++) {
+ ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1,
+ &buf[ec_byte - EEPROM_START], 1);
+ if (ret) {
+ printk(KERN_ERR "olpc-battery: EC command "
+ "EC_BAT_EEPROM @ 0x%x failed -"
+ " %d!\n", ec_byte, ret);
+ return -EIO;
+ }
+ }
+
+ return count;
+}
+
+static struct bin_attribute olpc_bat_eeprom = {
+ .attr = {
+ .name = "eeprom",
+ .mode = S_IRUGO,
+ .owner = THIS_MODULE,
+ },
+ .size = 0,
+ .read = olpc_bat_eeprom_read,
};
/*********************************************************************
@@ -290,8 +398,14 @@ static int __init olpc_bat_init(void)
if (!olpc_platform_info.ecver)
return -ENXIO;
- if (olpc_platform_info.ecver < 0x43) {
- printk(KERN_NOTICE "OLPC EC version 0x%02x too old for battery driver.\n", olpc_platform_info.ecver);
+
+ /*
+ * We've seen a number of EC protocol changes; this driver requires
+ * the latest EC protocol, supported by 0x44 and above.
+ */
+ if (olpc_platform_info.ecver < 0x44) {
+ printk(KERN_NOTICE "OLPC EC version 0x%02x too old for "
+ "battery driver.\n", olpc_platform_info.ecver);
return -ENXIO;
}
@@ -315,8 +429,14 @@ static int __init olpc_bat_init(void)
if (ret)
goto battery_failed;
+ ret = device_create_bin_file(olpc_bat.dev, &olpc_bat_eeprom);
+ if (ret)
+ goto eeprom_failed;
+
goto success;
+eeprom_failed:
+ power_supply_unregister(&olpc_bat);
battery_failed:
power_supply_unregister(&olpc_ac);
ac_failed:
@@ -327,6 +447,7 @@ success:
static void __exit olpc_bat_exit(void)
{
+ device_remove_bin_file(olpc_bat.dev, &olpc_bat_eeprom);
power_supply_unregister(&olpc_bat);
power_supply_unregister(&olpc_ac);
platform_device_unregister(bat_pdev);